CU/XLPE/SWA/PVC BS 5467 3G95 mm2

Description

Description

Standards

  • International
    IEC 60502
  • National
    BS 5467

Applications:

These cables with a low dielectric loss coupled with mechanical resistance are mainly used in energy networks with sudden load change residental or industrial areas. Can be laid outdoors, under grounds and in areas where sudden mechanical stress are expected

 

Construction:

  1. Conductor:Copper
  2. Insulation:XLPE
  3. Bedding:PVC
  4. Armour:Single layer galvanized steel wire
  5. Outer sheath:PVC

 

Marking:

ELECTRIC CABLE  600/1000 V  BS 5467  NEXANS i 
Nb. of cores  G cross section  "YEAR"  BASEC

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor shape
Sector-shaped stranded (SM)
Insulation
Extruded XLPE compound
Core identification
Blue, brown, green / yellow
Material of bedding
-
Inner sheath
PVC
Armour type
Steel wires
Outer sheath
PVC
Conductor flexibility
Class 2
Conductor material
Copper
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
95 mm²
Conductor diameter
13.7 mm
Average insulation thickness
1.1 mm
Thickness of the bedding
1.2 mm
Diameter of steel wires
2 mm
Approximate weight
4000 kg/km
Outer Diameter
36 mm

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
0.193 Ohm/km
Ohmical resistance of the armour
1.3 Ohm/km
Permissible current rating in open air
298 A
Permissible current rating when buried
226 A
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Weather resistance
Good
Short-circuit max. conductor temperature
250 °C
Operating temperature, range
-20 ... 60 °C
Minimum installation temperature
0 °C
Bending factor when laying
8 (xD)
Flame retardant
IEC 60332-1-2
Max. conductor temperature in service
90 °C

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000145-TRDE
  • Certification Date : 5/30/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1783
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close