NX600 5G4 mm2

Description

Description

Standards

  • Product
    BS 7846; BS 8519 cat. 3
  • Test
    BS 6387 CWZ

Application:

Designed for use in large complex buildings like stadiums, airports, hospitals, hi-rise offices and residential buildings, fully meets requirements to maintain circuit integrity even through the most extreme fire conditions.

Built to release low levels of toxic fumes when burning, for use with fire safety engineering systems such as:

• fire alarm systems

• emergency lighting

• other systems which help to ensure the safest evacuation and assist in the firefighting stages of a fire.

 

Construction:

  1. Conductor: Copper
  2. Fire barrier: Mica tape
  3. Insulation: XLPE
  4. Inner layer: Glass-fiber tape
  5. Bedding: LSZH
  6. Armour: Single layer of galvanized steel wires
  7. Outer layer: Glass-fiber tape
  8. Outer sheath: LSZH

 

NX600 cables should meet the F2 & F120 requirements of BS 6387 &  BS 8491 at 120 minutes for cables diameter over 20 mm

          • Resistance to fire, with mechanical shock and water jet

          • Additionally meeting the BS 8519 category 3 requirements

Marking:

ELECTRIC CABLE  600/1000 V  BS 7846-F120  NEXANS i  NX600  Number of cores x cross section  LPCB 946d/01  BASEC  ''YEAR'' 

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Armour type
Single layer of galvanized steel wires
Outer sheath
LSZH
Insulation
XLPE + Mica tape
Sheath colour
Black
Conductor flexibility
Class 2
Conductor shape
Circular stranded (RM)
Core identification
Blue, brown, black, grey, green / yellow
Halogen free
Yes
Inner sheath
None
Type of conductor
Circular, stranded, class 2

Dimensional characteristics

Dimensional characteristics

Number of cores
5
Approximate weight
1040 kg/km
Average insulation thickness
- mm
Conductor cross-section
4 mm²
Conductor diameter
- mm
Inner sheath thickness
- mm
Nominal outer diameter
24.0 mm
Nominal outer sheath thickness
- mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Max. DC resistance of the conductor at 20°C
4.61 Ohm/km
Permissible current rating clipped direct
42 A
Permissible current rating in open air
44 A
Permissible current rating when buried
36 A
Permissible short circuit current conductor 1s
0.6 kA
Voltage Drop
10.0 V/A.km

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
90 °C
Fire resistant
BS 8491 - 120 min
Smoke density
IEC 61034-1-2
Gases corrosivity
IEC 60754-2
Flame retardant
IEC 60332-3-24
Bending factor when laying
8 (xD)
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Selling & delivery Information

Marking
ELECTRIC CABLE 600/1000 V BS 7846-F120 NEXANS i NX600 Number of cores x cross section LPCB 946d/01 BASEC ''YEAR''

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close