- Newsroom
- Products
- Your Business
- Tools & Resources
- About Nexans
- People & Careers
- Documents
- Differentiated Offers
- CSR
- Search
- Contact us
- Compare
- Sign in
NX300 BS 6387 Multi Core Cables
NX300 BS 6387 Multi Core Cables
0,6/1 kV multi core low smoke halogen free, flame and fire resistant cables
Read moreNX300 2x1.5 mm2 BS 7846 - F2
Nexans ref. 10532124 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 260 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 26 A
- Permissible current rating when buried: 27 A
NX300 2x10 mm2 BS 7846 - F2
Nexans ref. 10532128 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 550 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 10 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 86 A
- Permissible current rating when buried: 77 A
NX300 2x16 mm2 BS 7846 - F2
Nexans ref. 10532129 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 700 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 16 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 115 A
- Permissible current rating when buried: 100 A
NX300 2x2.5 mm2 BS 7846 - F2
Nexans ref. 10532125 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 300 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 36 A
- Permissible current rating when buried: 35 A
NX300 2x25 mm2 BS 7846 - F2
Nexans ref. 10532130 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 25 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 149 A
- Permissible current rating when buried: 129 A
NX300 2x35 mm2 BS 7846 - F2
Nexans ref. 10532131 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1300 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 185 A
- Permissible current rating when buried: 155 A
NX300 2x4 mm2 BS 7846 - F2
Nexans ref. 10532126 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 360 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 49 A
- Permissible current rating when buried: 46 A
NX300 2x50 mm2 BS 7846 - F2
Nexans ref. 10532132 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1300 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 225 A
- Permissible current rating when buried: 183 A
NX300 2x6 mm2 BS 7846 - F2
Nexans ref. 10532127 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 420 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 63 A
- Permissible current rating when buried: 58 A
NX300 2x70 mm2 BS 7846 - F2
Nexans ref. 10532133 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1800 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 289 A
- Permissible current rating when buried: 225 A
NX300 2x95 mm2 BS 7846 - F2
Nexans ref. 10532134 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 2250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 95 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 352 A
- Permissible current rating when buried: 270 A
NX300 3G2.5 mm2 BS 7846 - F2
Nexans ref. 10550157 - Country ref. TR
- Outer sheath: LSZH
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, green / yellow
- Number of cores: 3
- Approximate weight: 320 kg/km
- Average insulation thickness: 0.7 mm
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.9 mm
- Nominal outer diameter: 16.0 mm
- Nominal outer sheath thickness: 1.8 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
NX300 3G4 mm2 BS 7846 - F2
Nexans ref. 10550158 - Country ref. TR
- Outer sheath: LSZH
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, green / yellow
- Number of cores: 3
- Approximate weight: 380 kg/km
- Average insulation thickness: 0.7 mm
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.5 mm
- Nominal outer diameter: 17.0 mm
- Nominal outer sheath thickness: 1.8 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
NX300 3x1.5 mm2 BS 7846 - F2
Nexans ref. 10532135 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 280 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
NX300 3x10 mm2 BS 7846 - F2
Nexans ref. 10532139 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 650 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 10 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
NX300 3x120 mm2 BS 7846 - F2
Nexans ref. 10532146 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 4250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 120 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 346 A
- Permissible current rating when buried: 257 A
NX300 3x150 mm2 BS 7846 - F2
Nexans ref. 10532147 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 5250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 150 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 399 A
- Permissible current rating when buried: 287 A
NX300 3x16 mm2 BS 7846 - F2
Nexans ref. 10532140 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 850 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 16 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
NX300 3x185 mm2 BS 7846 - F2
Nexans ref. 10532148 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 6250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 185 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating in open air: 456 A
- Permissible current rating when buried: 324 A
NX300 3x2.5 mm2 BS 7846 - F2
Nexans ref. 10532136 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 320 kg/km
- Average insulation thickness: 0.7 mm
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.97 mm
- Nominal outer diameter: 15.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
NX300 3x240 mm2 BS 7846 - F2
Nexans ref. 10532149 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 8000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 240 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating in open air: 538 A
- Permissible current rating when buried: 375 A
NX300 3x25 mm2 BS 7846 - F2
Nexans ref. 10532141 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 1200 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 25 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
NX300 3x300 mm2 BS 7846 - F2
Nexans ref. 10532150 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 10000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 300 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating in open air: 621 A
- Permissible current rating when buried: 419 A
NX300 3x35 mm2 BS 7846 - F2
Nexans ref. 10532142 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 1600 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
NX300 3x4 mm2 BS 7846 - F2
Nexans ref. 10532137 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 400 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
NX300 3x400 mm2 BS 7846 - F2
Nexans ref. 10532151 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 13000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 400 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 721 A
- Permissible current rating when buried: - A
NX300 3x50 mm2 BS 7846 - F2
Nexans ref. 10532143 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 1800 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
NX300 3x6 mm2 BS 7846 - F2
Nexans ref. 10532138 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 500 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
NX300 3x70 mm2 BS 7846 - F2
Nexans ref. 10532144 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 2500 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
NX300 3x95 mm2 BS 7846 - F2
Nexans ref. 10532145 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 3250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 95 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 298 A
- Permissible current rating when buried: 226 A
NX300 4x1.5 mm2 BS 7846 - F2
Nexans ref. 10532152 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 320 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
NX300 4x10 mm2 BS 7846 - F2
Nexans ref. 10532155 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 750 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 10 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
NX300 4x120 mm2 BS 7846 - F2
Nexans ref. 10532161 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 5500 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 120 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 346 A
- Permissible current rating when buried: 257 A
NX300 4x150 mm2 BS 7846 - F2
Nexans ref. 10532162 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 6750 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 150 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 399 A
- Permissible current rating when buried: 287 A
NX300 4x16 mm2 BS 7846 - F2
Nexans ref. 10532156 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 1100 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 16 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
NX300 4x185 mm2 BS 7846 - F2
Nexans ref. 10532163 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 8250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 185 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating in open air: 456 A
- Permissible current rating when buried: 324 A
NX300 4x2.5 mm2 BS 7846 - F2
Nexans ref. 10532153 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 380 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
NX300 4x240 mm2 BS 7846 - F2
Nexans ref. 10532164 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 10500 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 240 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating in open air: 538 A
- Permissible current rating when buried: 375 A
NX300 4x25 mm2 BS 7846 - F2
Nexans ref. 10532157 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 1500 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 25 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
NX300 4x300 mm2 BS 7846 - F2
Nexans ref. 10532165 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 13000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 300 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating in open air: 621 A
- Permissible current rating when buried: 419 A
NX300 4x35 mm2 BS 7846 - F2
Nexans ref. 10532158 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 1900 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
NX300 4x4 mm2 BS 7846 - F2
Nexans ref. 10532154 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 480 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
NX300 4x400 mm2 BS 7846 - F2
Nexans ref. 10532166 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 17000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 400 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 721 A
- Permissible current rating when buried: - A
NX300 4x50 mm2 BS 7846 - F2
Nexans ref. 10532159 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 2500 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
NX300 4x6 mm2 BS 7846 - F2
Nexans ref. 10532052 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 600 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
NX300 4x70 mm2 BS 7846 - F2
Nexans ref. 10532160 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 3250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
NX300 4x95 mm2 BS 7846 - F2
Nexans ref. 10532053 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 4250 kg/km
- Average insulation thickness: 1.1 mm
- Conductor cross-section: 95 mm²
- Conductor diameter: 13.7 mm
- Nominal outer diameter: 39.3 mm
- Nominal outer sheath thickness: 2.2 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 298 A
- Permissible current rating when buried: 226 A
Description
Description
Standards
-
ProductBS 7846
-
TestBS 6387
Application
Rafineries, mines, hotels, schools, tunnels, high constructions, hospitals, power plants , data processing centers, business centers where there is a concentration of sensitive to fire
Construction
- Conductor: Copper
- Fire barrier: Mica tape
- Insulation: XLPE
- Bedding: LSZH
- Outer sheath: LSZH
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania