NX300 BS 6387 Multi Core Cables

Products

NX300 2x1.5 mm2 BS 7846 - F2

Nexans ref. 10532124 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 260 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 26 A
  • Permissible current rating when buried: 27 A

 

NX300 2x10 mm2 BS 7846 - F2

Nexans ref. 10532128 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 550 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 10 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 86 A
  • Permissible current rating when buried: 77 A

 

NX300 2x16 mm2 BS 7846 - F2

Nexans ref. 10532129 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 700 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 16 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 115 A
  • Permissible current rating when buried: 100 A

 

NX300 2x2.5 mm2 BS 7846 - F2

Nexans ref. 10532125 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 300 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 36 A
  • Permissible current rating when buried: 35 A

 

NX300 2x25 mm2 BS 7846 - F2

Nexans ref. 10532130 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 1000 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 25 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 149 A
  • Permissible current rating when buried: 129 A

 

NX300 2x35 mm2 BS 7846 - F2

Nexans ref. 10532131 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 1300 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 185 A
  • Permissible current rating when buried: 155 A

 

NX300 2x4 mm2 BS 7846 - F2

Nexans ref. 10532126 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 360 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 49 A
  • Permissible current rating when buried: 46 A

 

NX300 2x50 mm2 BS 7846 - F2

Nexans ref. 10532132 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 1300 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 50 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 225 A
  • Permissible current rating when buried: 183 A

 

NX300 2x6 mm2 BS 7846 - F2

Nexans ref. 10532127 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 420 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 63 A
  • Permissible current rating when buried: 58 A

 

NX300 2x70 mm2 BS 7846 - F2

Nexans ref. 10532133 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 1800 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 70 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 289 A
  • Permissible current rating when buried: 225 A

 

NX300 2x95 mm2 BS 7846 - F2

Nexans ref. 10532134 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, Blue
  • Number of cores: 2
  • Approximate weight: 2250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 95 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 352 A
  • Permissible current rating when buried: 270 A

 

NX300 3G2.5 mm2 BS 7846 - F2

Nexans ref. 10550157 - Country ref. TR

  • Outer sheath: LSZH
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, green / yellow
  • Number of cores: 3
  • Approximate weight: 320 kg/km
  • Average insulation thickness: 0.7 mm
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.9 mm
  • Nominal outer diameter: 16.0 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A

 

NX300 3G4 mm2 BS 7846 - F2

Nexans ref. 10550158 - Country ref. TR

  • Outer sheath: LSZH
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, green / yellow
  • Number of cores: 3
  • Approximate weight: 380 kg/km
  • Average insulation thickness: 0.7 mm
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.5 mm
  • Nominal outer diameter: 17.0 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A

 

NX300 3x1.5 mm2 BS 7846 - F2

Nexans ref. 10532135 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 280 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 23 A

 

NX300 3x10 mm2 BS 7846 - F2

Nexans ref. 10532139 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 650 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 10 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A

 

NX300 3x120 mm2 BS 7846 - F2

Nexans ref. 10532146 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 4250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 120 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 346 A
  • Permissible current rating when buried: 257 A

 

NX300 3x150 mm2 BS 7846 - F2

Nexans ref. 10532147 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 5250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 150 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A

 

NX300 3x16 mm2 BS 7846 - F2

Nexans ref. 10532140 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 850 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 16 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A

 

NX300 3x185 mm2 BS 7846 - F2

Nexans ref. 10532148 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 6250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 185 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
  • Permissible current rating in open air: 456 A
  • Permissible current rating when buried: 324 A

 

NX300 3x2.5 mm2 BS 7846 - F2

Nexans ref. 10532136 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 320 kg/km
  • Average insulation thickness: 0.7 mm
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.97 mm
  • Nominal outer diameter: 15.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A

 

NX300 3x240 mm2 BS 7846 - F2

Nexans ref. 10532149 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 8000 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 240 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
  • Permissible current rating in open air: 538 A
  • Permissible current rating when buried: 375 A

 

NX300 3x25 mm2 BS 7846 - F2

Nexans ref. 10532141 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 1200 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 25 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A

 

NX300 3x300 mm2 BS 7846 - F2

Nexans ref. 10532150 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 10000 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 300 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
  • Permissible current rating in open air: 621 A
  • Permissible current rating when buried: 419 A

 

NX300 3x35 mm2 BS 7846 - F2

Nexans ref. 10532142 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 1600 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A

 

NX300 3x4 mm2 BS 7846 - F2

Nexans ref. 10532137 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 400 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A

 

NX300 3x400 mm2 BS 7846 - F2

Nexans ref. 10532151 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 13000 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 400 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 721 A
  • Permissible current rating when buried: - A

 

NX300 3x50 mm2 BS 7846 - F2

Nexans ref. 10532143 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 1800 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 50 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A

 

NX300 3x6 mm2 BS 7846 - F2

Nexans ref. 10532138 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 500 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A

 

NX300 3x70 mm2 BS 7846 - F2

Nexans ref. 10532144 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 2500 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 70 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A

 

NX300 3x95 mm2 BS 7846 - F2

Nexans ref. 10532145 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Approximate weight: 3250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 95 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 298 A
  • Permissible current rating when buried: 226 A

 

NX300 4x1.5 mm2 BS 7846 - F2

Nexans ref. 10532152 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 320 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 23 A
  • Permissible current rating when buried: 23 A

 

NX300 4x10 mm2 BS 7846 - F2

Nexans ref. 10532155 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 750 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 10 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A

 

NX300 4x120 mm2 BS 7846 - F2

Nexans ref. 10532161 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 5500 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 120 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 346 A
  • Permissible current rating when buried: 257 A

 

NX300 4x150 mm2 BS 7846 - F2

Nexans ref. 10532162 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 6750 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 150 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A

 

NX300 4x16 mm2 BS 7846 - F2

Nexans ref. 10532156 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 1100 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 16 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A

 

NX300 4x185 mm2 BS 7846 - F2

Nexans ref. 10532163 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 8250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 185 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
  • Permissible current rating in open air: 456 A
  • Permissible current rating when buried: 324 A

 

NX300 4x2.5 mm2 BS 7846 - F2

Nexans ref. 10532153 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 380 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A

 

NX300 4x240 mm2 BS 7846 - F2

Nexans ref. 10532164 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 10500 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 240 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
  • Permissible current rating in open air: 538 A
  • Permissible current rating when buried: 375 A

 

NX300 4x25 mm2 BS 7846 - F2

Nexans ref. 10532157 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 1500 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 25 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A

 

NX300 4x300 mm2 BS 7846 - F2

Nexans ref. 10532165 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 13000 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 300 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
  • Permissible current rating in open air: 621 A
  • Permissible current rating when buried: 419 A

 

NX300 4x35 mm2 BS 7846 - F2

Nexans ref. 10532158 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 1900 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A

 

NX300 4x4 mm2 BS 7846 - F2

Nexans ref. 10532154 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 480 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A

 

NX300 4x400 mm2 BS 7846 - F2

Nexans ref. 10532166 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 17000 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 400 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 721 A
  • Permissible current rating when buried: - A

 

NX300 4x50 mm2 BS 7846 - F2

Nexans ref. 10532159 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 2500 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 50 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A

 

NX300 4x6 mm2 BS 7846 - F2

Nexans ref. 10532052 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 600 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A

 

NX300 4x70 mm2 BS 7846 - F2

Nexans ref. 10532160 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 3250 kg/km
  • Average insulation thickness: - mm
  • Conductor cross-section: 70 mm²
  • Conductor diameter: - mm
  • Nominal outer diameter: - mm
  • Nominal outer sheath thickness: - mm
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 246 A
  • Permissible current rating when buried: 188 A

 

NX300 4x95 mm2 BS 7846 - F2

Nexans ref. 10532053 - Country ref. TR

  • Packaging: Drum (1000m)
  • Outer sheath: HFFR (Halogen Free Flame Retardant)
  • Conductor shape: Sector-shaped stranded (SM)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Approximate weight: 4250 kg/km
  • Average insulation thickness: 1.1 mm
  • Conductor cross-section: 95 mm²
  • Conductor diameter: 13.7 mm
  • Nominal outer diameter: 39.3 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 298 A
  • Permissible current rating when buried: 226 A

 

Description

Description

Standards

  • Product
    BS 7846
  • Test
    BS 6387

Application

Rafineries, mines, hotels, schools, tunnels, high constructions, hospitals, power plants , data processing centers, business centers where there is a concentration of sensitive to fire

Construction

  1. Conductor: Copper
  2. Fire barrier: Mica tape
  3. Insulation: XLPE
  4. Bedding: LSZH
  5. Outer sheath: LSZH

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE + Mica tape
Sheath colour
Black
Conductor flexibility
Stranded class 2
Halogen free
IEC 60754-1
Type of conductor
Circular, stranded, class 2

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Fire resistant
BS 6387 CWZ
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Flame retardant
IEC 60332-3-24
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close