N2XH FE 180 1x6 mm2

Description

Description

Standards

  • Product
    IEC 60502-1

Application

  • Indoor applications where fire safety is a priority (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.)
  • Systems that require 180 minutes of circuit integrity during fire conditions:

                   - Warning Systems (fire alarms, smoke detection/alarm devices)

                   - Smoke Ventilation Systems (tunnel fans)

                   - Emergency Exits (emergency lighting fixtures)

                   - Fire Intervention Systems (water pumps, automatic doors)

                   - Uninterruptible Energy Systems (escalators, elevators in subways)

Construction

  1. Conductor:Copper
  2. Fire proof:Mica tape
  3. Insulation:XLPE
  4. Outher sheath:LSZH (Low smoke zero halogen)

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2
Conductor material
Copper
Conductor shape
Circular stranded (RM)
Core identification
Black
Halogen free
IEC 60754-1
Insulation
XLPE (chemical)
Outer sheath
HFFR (Halogen Free Flame Retardant)
Sheath colour
Orange

Dimensional characteristics

Dimensional characteristics

Approximate weight
100 kg/km
Conductor cross-section
6 mm²
Nominal outer diameter
7.5 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
3.08 Ohm/km
Perm. current rating buried 20°C - trefoil formation
49 A
Perm. current rating in air 30°C - trefoil formation
- A
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Bending factor when laying
12 (xD)
Fire resistant
IEC 60331-21
Flame retardant
IEC 60332-3 Cat. C
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Smoke density
IEC 61034

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close