NX400 BS 7846-F2 Armoured Cables
NX400 BS 7846-F2 Armoured Cables
0,6/1 kV multi core low smoke halogen free, flame and fire resistant cables
Read moreNX400 10x1.5 mm2 BS 7846 - F2
Nexans ref. 10535861 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 10
- Approximate weight: 900 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 24.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 12 A
- Permissible current rating in open air: 14 A
- Permissible current rating when buried: 11 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 10x2.5 mm2 BS 7846 - F2
Nexans ref. 10535864 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 10
- Approximate weight: 1100 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 25.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 17 A
- Permissible current rating in open air: 18 A
- Permissible current rating when buried: 15 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 10x4 mm2 BS 7846 - F2
Nexans ref. 10535867 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 10
- Approximate weight: 1400 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 23 A
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 20 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 12.0 V/A.km
NX400 12x1.5 mm2 BS 7846 - F2
Nexans ref. 10527024 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 12
- Approximate weight: 900 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 24.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 12 A
- Permissible current rating in open air: 13 A
- Permissible current rating when buried: 11 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 12x2.5 mm2 BS 7846 - F2
Nexans ref. 10531448 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 12
- Approximate weight: 1100 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 25.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 16 A
- Permissible current rating in open air: 17 A
- Permissible current rating when buried: 14 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 12x4 mm2 BS 7846 - F2
Nexans ref. 10535869 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 12
- Approximate weight: 1400 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 22 A
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 19 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 12.0 V/A.km
NX400 19x1.5 mm2 BS 7846 - F2
Nexans ref. 10535870 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 19
- Approximate weight: 1200 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 27.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 10 A
- Permissible current rating in open air: 11 A
- Permissible current rating when buried: 9 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 19x2.5 mm2 BS 7846 - F2
Nexans ref. 10531468 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 19
- Approximate weight: 1600 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 30.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 13 A
- Permissible current rating in open air: 14 A
- Permissible current rating when buried: 12 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 19x4 mm2 BS 7846 - F2
Nexans ref. 10535872 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 19
- Approximate weight: 2000 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 33.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 18 A
- Permissible current rating in open air: 19 A
- Permissible current rating when buried: 16 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 12.0 V/A.km
NX400 27x1.5 mm2 BS 7846 - F2
Nexans ref. 10536187 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 27
- Approximate weight: 1700 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 32.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 9 A
- Permissible current rating in open air: 10 A
- Permissible current rating when buried: 8 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 27x1.5 mm2 BS 7846 - F2
Nexans ref. 10562830 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 27
- Approximate weight: 1530 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 31.1 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 27x2.5 mm2 BS 7846 - F2
Nexans ref. 10536188 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 27
- Approximate weight: 2000 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 35.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 12 A
- Permissible current rating in open air: 13 A
- Permissible current rating when buried: 11 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 2x1.5 mm2 BS 7846 - F2
Nexans ref. 10518579 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 320 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 13.8 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 27 A
- Permissible current rating in open air: 29 A
- Permissible current rating when buried: 25 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 2x10 mm2 BS 7846 - F2
Nexans ref. 10518574 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 650 kg/km
- Conductor cross-section: 10 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 18.7 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating clipped direct: 85 A
- Permissible current rating in open air: 90 A
- Permissible current rating when buried: 71 A
- Permissible short circuit current conductor 1s: 1.4 kA
- Voltage Drop: 4.7 V/A.km
NX400 2x16 mm2 BS 7846 - F2
Nexans ref. 10516766 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 900 kg/km
- Conductor cross-section: 16 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 20.7 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating clipped direct: 110 A
- Permissible current rating in open air: 115 A
- Permissible current rating when buried: 91 A
- Permissible short circuit current conductor 1s: 2.3 kA
- Voltage Drop: 2.9 V/A.km
NX400 2x2.5 mm2 BS 7846 - F2
Nexans ref. 10518577 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 380 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 14.6 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 36 A
- Permissible current rating in open air: 39 A
- Permissible current rating when buried: 33 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 2x25 mm2 BS 7846 - F2
Nexans ref. 10516765 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1200 kg/km
- Conductor cross-section: 25 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 23.8 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating clipped direct: 146 A
- Permissible current rating in open air: 152 A
- Permissible current rating when buried: 116 A
- Permissible short circuit current conductor 1s: 3.6 kA
- Voltage Drop: 1.9 V/A.km
NX400 2x35 mm2 BS 7846 - F2
Nexans ref. 10516764 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1700 kg/km
- Conductor cross-section: 35 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 26.7 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating clipped direct: 180 A
- Permissible current rating in open air: 188 A
- Permissible current rating when buried: 162 A
- Permissible short circuit current conductor 1s: 5 kA
- Voltage Drop: 1.35 V/A.km
NX400 2x4 mm2 BS 7846 - F2
Nexans ref. 10518576 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 440 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 15.7 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 49 A
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 43 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 12.0 V/A.km
NX400 2x50 mm2 BS 7846 - F2
Nexans ref. 10516763 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 1700 kg/km
- Conductor cross-section: 50 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 24.9 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating clipped direct: 219 A
- Permissible current rating in open air: 228 A
- Permissible current rating when buried: 197 A
- Permissible short circuit current conductor 1s: 7.2 kA
- Voltage Drop: 1.0 V/A.km
NX400 2x6 mm2 BS 7846 - F2
Nexans ref. 10518575 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 550 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 17.3 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: 62 A
- Permissible current rating in open air: 66 A
- Permissible current rating when buried: 53 A
- Permissible short circuit current conductor 1s: 0.9 kA
- Voltage Drop: 7.9 V/A.km
NX400 2x70 mm2 BS 7846 - F2
Nexans ref. 10516762 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 2250 kg/km
- Conductor cross-section: 70 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 27.9 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating clipped direct: 279 A
- Permissible current rating in open air: 291 A
- Permissible current rating when buried: 251 A
- Permissible short circuit current conductor 1s: 10 kA
- Voltage Drop: 0.69 V/A.km
NX400 2x95 mm2 BS 7846 - F2
Nexans ref. 10517794 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, Blue
- Number of cores: 2
- Approximate weight: 3000 kg/km
- Conductor cross-section: 95 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 31.7 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating clipped direct: 338 A
- Permissible current rating in open air: 354 A
- Permissible current rating when buried: 239 A
- Permissible short circuit current conductor 1s: 13.6 kA
- Voltage Drop: 0.52 V/A.km
NX400 37x1.5 mm2 BS 7846 - F2
Nexans ref. 10536189 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 37
- Approximate weight: 2000 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 36.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 8 A
- Permissible current rating in open air: 9 A
- Permissible current rating when buried: 7 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 37x2.5 mm2 BS 7846 - F2
Nexans ref. 10536190 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 37
- Approximate weight: 2500 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 39.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 11 A
- Permissible current rating in open air: 11 A
- Permissible current rating when buried: 10 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 3G1.5 mm2 BS 7846 - F2
Nexans ref. 10562831 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 3
- Approximate weight: 330 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 14.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 3G1.5 mm2 BS 7846 - F2
Nexans ref. 10565131 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 3
- Approximate weight: 330 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 14.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 3G2.5 mm2 BS 7846 - F2
Nexans ref. 10564463 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 3
- Approximate weight: 390 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 14.9 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 3G2.5 mm2 BS 7846 - F2
Nexans ref. 10563413 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 3
- Approximate weight: 390 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 14.9 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 3G4 mm2 BS 7846 - F2
Nexans ref. 10564462 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 3
- Approximate weight: 480 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 16.4 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 3G6 mm2 BS 7846 - F2
Nexans ref. 10566728 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 3
- Approximate weight: 570 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 17.6 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 3x1.5 mm2 BS 7846 - F2
Nexans ref. 10517795 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 360 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 14.4 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 23 A
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 21 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 27.0 V/A.km
NX400 3x10 mm2 BS 7846 - F2
Nexans ref. 10518624 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 900 kg/km
- Conductor cross-section: 10 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 20.4 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating clipped direct: 73 A
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 58 A
- Permissible short circuit current conductor 1s: 1.4 kA
- Voltage Drop: 4.0 V/A.km
NX400 3x120 mm2 BS 7846 - F2
Nexans ref. 10517963 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 5000 kg/km
- Conductor cross-section: 120 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 40.7 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating clipped direct: 335 A
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 223 A
- Permissible short circuit current conductor 1s: 17.2 kA
- Voltage Drop: 0.37 V/A.km
NX400 3x150 mm2 BS 7846 - F2
Nexans ref. 10516767 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 6500 kg/km
- Conductor cross-section: 150 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 45.6 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating clipped direct: 386 A
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 251 A
- Permissible short circuit current conductor 1s: 21.4 kA
- Voltage Drop: 0.3 V/A.km
NX400 3x16 mm2 BS 7846 - F2
Nexans ref. 10518625 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 1100 kg/km
- Conductor cross-section: 16 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 21.8 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating clipped direct: 94 A
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 75 A
- Permissible short circuit current conductor 1s: 2.3 kA
- Voltage Drop: 2.5 V/A.km
NX400 3x185 mm2 BS 7846 - F2
Nexans ref. 10516768 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 7750 kg/km
- Conductor cross-section: 185 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 49.6 mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating clipped direct: 441 A
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 281 A
- Permissible short circuit current conductor 1s: 26.5 kA
- Voltage Drop: 0.26 V/A.km
NX400 3x2.5 mm2 BS 7846 - F2
Nexans ref. 10518621 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 420 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 15.3 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 31 A
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 28 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 16.0 V/A.km
NX400 3x240 mm2 BS 7846 - F2
Nexans ref. 10516769 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 9500 kg/km
- Conductor cross-section: 240 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 54.8 mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating clipped direct: 520 A
- Permissible current rating in open air: 546 A
- Permissible current rating when buried: 324 A
- Permissible short circuit current conductor 1s: 34.3 kA
- Voltage Drop: 0.21 V/A.km
NX400 3x25 mm2 BS 7846 - F2
Nexans ref. 10518626 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 1600 kg/km
- Conductor cross-section: 25 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 26.1 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating clipped direct: 124 A
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 96 A
- Permissible short circuit current conductor 1s: 3.6 kA
- Voltage Drop: 1.65 V/A.km
NX400 3x300 mm2 BS 7846 - F2
Nexans ref. 10516770 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 11500 kg/km
- Conductor cross-section: 300 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 59.8 mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating clipped direct: 599 A
- Permissible current rating in open air: 628 A
- Permissible current rating when buried: 365 A
- Permissible short circuit current conductor 1s: 42.9 kA
- Voltage Drop: 0.18 V/A.km
NX400 3x35 mm2 BS 7846 - F2
Nexans ref. 10517802 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 2000 kg/km
- Conductor cross-section: 35 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.5 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating clipped direct: 154 A
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 115 A
- Permissible short circuit current conductor 1s: 5 kA
- Voltage Drop: 1.15 V/A.km
NX400 3x4 mm2 BS 7846 - F2
Nexans ref. 10518622 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 500 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 16.9 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 42 A
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 36 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 10.0 V/A.km
NX400 3x400 mm2 BS 7846 - F2
Nexans ref. 10516771 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 14500 kg/km
- Conductor cross-section: 400 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 67.7 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating clipped direct: 673 A
- Permissible current rating in open air: 728 A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: 57.2 kA
- Voltage Drop: 0.17 V/A.km
NX400 3x50 mm2 BS 7846 - F2
Nexans ref. 10517966 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 2250 kg/km
- Conductor cross-section: 50 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.5 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating clipped direct: 187 A
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 135 A
- Permissible short circuit current conductor 1s: 7.2 kA
- Voltage Drop: 0.87 V/A.km
NX400 3x6 mm2 BS 7846 - F2
Nexans ref. 10518623 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 600 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 18.2 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: 53 A
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 44 A
- Permissible short circuit current conductor 1s: 0.9 kA
- Voltage Drop: 6.8 V/A.km
NX400 3x70 mm2 BS 7846 - F2
Nexans ref. 10517965 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 3000 kg/km
- Conductor cross-section: 70 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 32.2 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating clipped direct: 238 A
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 167 A
- Permissible short circuit current conductor 1s: 10 kA
- Voltage Drop: 0.6 V/A.km
NX400 3x95 mm2 BS 7846 - F2
Nexans ref. 10517964 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Brown, black, grey
- Number of cores: 3
- Approximate weight: 4000 kg/km
- Conductor cross-section: 95 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 36.9 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating clipped direct: 289 A
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 197 A
- Permissible short circuit current conductor 1s: 13.6 kA
- Voltage Drop: 0.45 V/A.km
NX400 4x1.5 mm2 BS 7846 - F2
Nexans ref. 10518627 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 400 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 15.4 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 23 A
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 21 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 27.0 V/A.km
NX400 4x10 mm2 BS 7846 - F2
Nexans ref. 10518631 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 1100 kg/km
- Conductor cross-section: 10 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 22.0 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating clipped direct: 73 A
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 58 A
- Permissible short circuit current conductor 1s: 1.4 kA
- Voltage Drop: 4.0 V/A.km
NX400 4x120 mm2 BS 7846 - F2
Nexans ref. 10518638 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 6750 kg/km
- Conductor cross-section: 120 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 46.9 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating clipped direct: 335 A
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 223 A
- Permissible short circuit current conductor 1s: 17.2 kA
- Voltage Drop: 0.37 V/A.km
NX400 4x150 mm2 BS 7846 - F2
Nexans ref. 10518639 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 8250 kg/km
- Conductor cross-section: 150 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 51.4 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating clipped direct: 386 A
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 251 A
- Permissible short circuit current conductor 1s: 21.4 kA
- Voltage Drop: 0.3 V/A.km
NX400 4x16 mm2 BS 7846 - F2
Nexans ref. 10518632 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 1300 kg/km
- Conductor cross-section: 16 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 23.6 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating clipped direct: 94 A
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 75 A
- Permissible short circuit current conductor 1s: 2.3 kA
- Voltage Drop: 2.5 V/A.km
NX400 4x185 mm2 BS 7846 - F2
Nexans ref. 10518641 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 9750 kg/km
- Conductor cross-section: 185 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 56.0 mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating clipped direct: 441 A
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 281 A
- Permissible short circuit current conductor 1s: 26.5 kA
- Voltage Drop: 0.26 V/A.km
NX400 4x2.5 mm2 BS 7846 - F2
Nexans ref. 10518628 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 500 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 16.9 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 31 A
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 28 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 16.0 V/A.km
NX400 4x240 mm2 BS 7846 - F2
Nexans ref. 10518642 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 12500 kg/km
- Conductor cross-section: 240 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 62.3 mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating clipped direct: 520 A
- Permissible current rating in open air: 546 A
- Permissible current rating when buried: 324 A
- Permissible short circuit current conductor 1s: 34.3 kA
- Voltage Drop: 0.21 V/A.km
NX400 4x25 mm2 BS 7846 - F2
Nexans ref. 10518633 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 2000 kg/km
- Conductor cross-section: 25 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.3 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating clipped direct: 124 A
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 96 A
- Permissible short circuit current conductor 1s: 3.6 kA
- Voltage Drop: 1.65 V/A.km
NX400 4x300 mm2 BS 7846 - F2
Nexans ref. 10518569 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 15000 kg/km
- Conductor cross-section: 300 mm²
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 68.3 mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating clipped direct: 599 A
- Permissible current rating in open air: 628 A
- Permissible current rating when buried: 365 A
- Permissible short circuit current conductor 1s: 42.9 kA
- Voltage Drop: 0.18 V/A.km
NX400 4x35 mm2 BS 7846 - F2
Nexans ref. 10518634 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 2500 kg/km
- Conductor cross-section: 35 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 30.9 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating clipped direct: 154 A
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 115 A
- Permissible short circuit current conductor 1s: 5 kA
- Voltage Drop: 1.15 V/A.km
NX400 4x4 mm2 BS 7846 - F2
Nexans ref. 10518629 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 600 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 18.2 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 42 A
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 36 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 10.0 V/A.km
NX400 4x400 mm2 BS 7846 - F2
Nexans ref. 10518570 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 20000 kg/km
- Conductor cross-section: 400 mm²
- Nominal armour wire diameter: 3.15 mm
- Nominal outer diameter: 79.5 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating clipped direct: 673 A
- Permissible current rating in open air: 728 A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: 57.2 kA
- Voltage Drop: 0.17 V/A.km
NX400 4x50 mm2 BS 7846 - F2
Nexans ref. 10518635 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 3000 kg/km
- Conductor cross-section: 50 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 32.1 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating clipped direct: 187 A
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 135 A
- Permissible short circuit current conductor 1s: 7.2 kA
- Voltage Drop: 0.87 V/A.km
NX400 4x6 mm2 BS 7846 - F2
Nexans ref. 10518630 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 800 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 20.4 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: 53 A
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 44 A
- Permissible short circuit current conductor 1s: 0.9 kA
- Voltage Drop: 6.8 V/A.km
NX400 4x6 mm2 BS 7846 - F2
Nexans ref. 10520452 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: -
- Number of cores: 4
- Approximate weight: 770 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 19.7 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 4x70 mm2 BS 7846 - F2
Nexans ref. 10518636 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 4250 kg/km
- Conductor cross-section: 70 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 37.3 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating clipped direct: 238 A
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 167 A
- Permissible short circuit current conductor 1s: 10 kA
- Voltage Drop: 0.6 V/A.km
NX400 4x95 mm2 BS 7846 - F2
Nexans ref. 10518637 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Sector-shaped stranded (SM)
- Core identification: Blue, brown, black, grey
- Number of cores: 4
- Approximate weight: 5250 kg/km
- Conductor cross-section: 95 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 41.9 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating clipped direct: 289 A
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 197 A
- Permissible short circuit current conductor 1s: 13.6 kA
- Voltage Drop: 0.45 V/A.km
NX400 5G1.5 mm2 BS 7846 - F2
Nexans ref. 10536324 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 480 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 17.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 23 A
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 21 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 27.0 V/A.km
NX400 5G1.5 mm2 BS 7846 - F2
Nexans ref. 10563414 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 450 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 16.5 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 5G10 mm2 BS 7846 - F2
Nexans ref. 10519118 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 1200 kg/km
- Conductor cross-section: 10 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 24.0 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating clipped direct: 73 A
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 58 A
- Permissible short circuit current conductor 1s: 1.4 kA
- Voltage Drop: 4.0 V/A.km
NX400 5G16 mm2 BS 7846 - F2
Nexans ref. 10526192 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 1700 kg/km
- Conductor cross-section: 16 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 27.0 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating clipped direct: 94 A
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 75 A
- Permissible short circuit current conductor 1s: 2.3 kA
- Voltage Drop: 2.5 V/A.km
NX400 5G2.5 mm2 BS 7846 - F2
Nexans ref. 10536325 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 550 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 18.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 31 A
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 28 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 16.0 V/A.km
NX400 5G2.5 mm2 BS 7846 - F2
Nexans ref. 10563415 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 530 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 17.6 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 5G25 mm2 BS 7846 - F2
Nexans ref. 10530521 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 2500 kg/km
- Conductor cross-section: 25 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 31.0 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating clipped direct: 124 A
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 96 A
- Permissible short circuit current conductor 1s: 3.6 kA
- Voltage Drop: 1.65 V/A.km
NX400 5G35 mm2 BS 7846 - F2
Nexans ref. 10536326 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 3000 kg/km
- Conductor cross-section: 35 mm²
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 34.0 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating clipped direct: 154 A
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 115 A
- Permissible short circuit current conductor 1s: 5 kA
- Voltage Drop: 1.15 V/A.km
NX400 5G4 mm2 BS 7846 - F2
Nexans ref. 10536327 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 700 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 20.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 42 A
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 36 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 10.0 V/A.km
NX400 5G50 mm2 BS 7846 - F2
Nexans ref. 10536328 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 4000 kg/km
- Conductor cross-section: 50 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 39.0 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating clipped direct: 187 A
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 135 A
- Permissible short circuit current conductor 1s: 7.2 kA
- Voltage Drop: 0.87 V/A.km
NX400 5G6 mm2 BS 7846 - F2
Nexans ref. 10530507 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 950 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 22.0 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: 53 A
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 44 A
- Permissible short circuit current conductor 1s: 0.9 kA
- Voltage Drop: 6.8 V/A.km
NX400 5G70 mm2 BS 7846 - F2
Nexans ref. 10536329 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Approximate weight: 5500 kg/km
- Conductor cross-section: 70 mm²
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 45.0 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating clipped direct: 238 A
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 167 A
- Permissible short circuit current conductor 1s: 10 kA
- Voltage Drop: 0.6 V/A.km
NX400 5x1.5 mm2 BS 7846 - F2
Nexans ref. 10562867 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 5
- Approximate weight: 450 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 16.5 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 5x10 mm2 BS 7846 - F2
Nexans ref. 10557111 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 5
- Approximate weight: 1150 kg/km
- Conductor cross-section: 10 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 23.3 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 5x16 mm2 BS 7846 - F2
Nexans ref. 10557112 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 5
- Approximate weight: 1630 kg/km
- Conductor cross-section: 16 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 26.5 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 5x2.5 mm2 BS 7846 - F2
Nexans ref. 10557110 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 5
- Approximate weight: 530 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 17.6 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 5x6 mm2 BS 7846 - F2
Nexans ref. 10518988 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 5
- Approximate weight: 880 kg/km
- Conductor cross-section: 6 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 21.2 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 7x1.5 mm2 BS 7846 - F2
Nexans ref. 10526191 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 7
- Approximate weight: 550 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 18.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: 14 A
- Permissible current rating in open air: 15 A
- Permissible current rating when buried: 13 A
- Permissible short circuit current conductor 1s: 0.2 kA
- Voltage Drop: 31.0 V/A.km
NX400 7x1.5 mm2 BS 7846 - F2
Nexans ref. 10562829 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 7
- Approximate weight: 520 kg/km
- Conductor cross-section: 1.5 mm²
- Nominal armour wire diameter: - mm
- Nominal outer diameter: 17.6 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating clipped direct: - A
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
- Permissible short circuit current conductor 1s: - kA
- Voltage Drop: - V/A.km
NX400 7x2.5 mm2 BS 7846 - F2
Nexans ref. 10530112 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 7
- Approximate weight: 650 kg/km
- Conductor cross-section: 2.5 mm²
- Nominal armour wire diameter: 0.9 mm
- Nominal outer diameter: 20.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating clipped direct: 19 A
- Permissible current rating in open air: 20 A
- Permissible current rating when buried: 17 A
- Permissible short circuit current conductor 1s: 0.4 kA
- Voltage Drop: 19.0 V/A.km
NX400 7x4 mm2 BS 7846 - F2
Nexans ref. 10531447 - Country ref. TR
- Packaging: Drum (1000m)
- Conductor shape: Circular stranded (RM)
- Core identification: Numbers
- Number of cores: 7
- Approximate weight: 900 kg/km
- Conductor cross-section: 4 mm²
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 22.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating clipped direct: 26 A
- Permissible current rating in open air: 27 A
- Permissible current rating when buried: 22 A
- Permissible short circuit current conductor 1s: 0.6 kA
- Voltage Drop: 12.0 V/A.km
Description
Description
Standards
-
ProductBS 7846
-
TestBS 6387 CWZ; EN 50200
Application
Rafineries, mines, hotels, schools, tunnels, high constructions, hospitals, power plants, data processing centers, business centers where there is a concentration of sensitive to fire
Construction
- Conductor: Copper
- Fire barrier: Mica tape
- Insulation: XLPE
- Bedding: LSZH
- Armour: Single layer of galvanized steel wires
- Outer sheath: LSZH
NX400 cables should meet the F2 requirements according to BS 6387
- Resistance to fire alone, Protocol C
- Resistance to fire with water, Protocol W
- Resistance to fire with mechanical shock, Protocol Z
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Marking
ELECTRIC CABLE 600/1000 V BS 7846-F2 NEXANS i NX400 Number of cores x cross section BASEC LPCB 946a/01 "YEAR"