NX300 BS 6387 Single Core Cables
NX300 BS 6387 Single Core Cables
Fire-resistant, single-core, multi-wire copper conductor power cables, halogen-free and fire-safe. Thanks to their low smoke density, non-flame propagating properties and no corrosive gas emissions for protecting life and property in case of fire. They maintain circuit integrity for 180 minutes under 950 °C. Moreover, they are resistant to mechanical impact and water during fire conditions.
Read moreNX300 1x1000 mm2 BS 6387
Nexans ref. 10532123 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 10000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 1000 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.018 Ohm/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
NX300 1x120 mm2 BS 6387
Nexans ref. 10532114 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 1300 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 120 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 383 A
- Permissible current rating when buried: 257 A
NX300 1x150 mm2 BS 6387
Nexans ref. 10532115 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 1600 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 150 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 287 A
NX300 1x185 mm2 BS 6387
Nexans ref. 10532116 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 1900 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 185 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
- Permissible current rating in open air: 510 A
- Permissible current rating when buried: 324 A
NX300 1x240 mm2 BS 6387
Nexans ref. 10532117 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: Stranded class 2
- Approximate weight: 2500 kg/km
- Average insulation thickness: 1.7 mm
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.3 mm
- Nominal outer diameter: 26.5 mm
- Nominal outer sheath thickness: 1.8 mm
- Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
- Permissible current rating in open air: 607 A
- Permissible current rating when buried: 375 A
NX300 1x300 mm2 BS 6387
Nexans ref. 10532118 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 3000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 300 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Permissible current rating in open air: 703 A
- Permissible current rating when buried: 419 A
NX300 1x400 mm2 BS 6387
Nexans ref. 10532119 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: Stranded class 2
- Approximate weight: 4000 kg/km
- Average insulation thickness: 2.0 mm
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.2 mm
- Nominal outer diameter: 32.4 mm
- Nominal outer sheath thickness: 2.0 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 823 A
- Permissible current rating when buried: 464 A
NX300 1x50 mm2 BS 6387
Nexans ref. 10532111 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 550 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 207 A
- Permissible current rating when buried: 153 A
NX300 1x500 mm2 BS 6387
Nexans ref. 10532120 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 5000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 500 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.037 Ohm/km
- Permissible current rating in open air: 946 A
- Permissible current rating when buried: - A
NX300 1x630 mm2 BS 6387
Nexans ref. 10532121 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 6250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 630 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.028 Ohm/km
- Permissible current rating in open air: 1088 A
- Permissible current rating when buried: - A
NX300 1x70 mm2 BS 6387
Nexans ref. 10532112 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 750 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 268 A
- Permissible current rating when buried: 188 A
NX300 1x70 mm2 BS 6387
Nexans ref. 10544249 - Country ref. TR
- Outer sheath: LSZH
- Conductor flexibility: Class 2
- Approximate weight: 760 kg/km
- Average insulation thickness: 1.1 mm
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.6 mm
- Nominal outer diameter: 17.0 mm
- Nominal outer sheath thickness: 1.6 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 268 A
- Permissible current rating when buried: 188 A
NX300 1x800 mm2 BS 6387
Nexans ref. 10532122 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 8250 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 800 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.022 Ohm/km
- Permissible current rating in open air: - A
- Permissible current rating when buried: - A
NX300 1x95 mm2 BS 6387
Nexans ref. 10532113 - Country ref. TR
- Packaging: Drum (1000m)
- Outer sheath: HFFR (Halogen Free Flame Retardant)
- Conductor flexibility: -
- Approximate weight: 1000 kg/km
- Average insulation thickness: - mm
- Conductor cross-section: 95 mm²
- Conductor diameter: - mm
- Nominal outer diameter: - mm
- Nominal outer sheath thickness: - mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 328 A
- Permissible current rating when buried: 226 A
NX300 1x95 mm2 BS 6387
Nexans ref. 10556228 - Country ref. TR
- Outer sheath: LSZH
- Conductor flexibility: Class 2
- Approximate weight: 1030 kg/km
- Average insulation thickness: 1.1 mm
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.4 mm
- Nominal outer diameter: 19.0 mm
- Nominal outer sheath thickness: 1.7 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 328 A
- Permissible current rating when buried: 226 A
Description
Description
Standards
-
ProductBS 7846
-
TestBS 6387
Application
- Indoor applications where fire safety is a priority (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.)
- Systems that require 180 minutes of circuit integrity during fire conditions:
- Warning Systems (fire alarms, smoke detection/alarm devices)
- Smoke Ventilation Systems (tunnel fans)
- Emergency Exits (emergency lighting fixtures)
- Fire Intervention Systems (water pumps, automatic doors)
- Uninterruptible Energy Systems (escalators, elevators in subways)
Construction
- Conductor: Copper
- Fire barrier: Mica tape
- Insulation: XLPE
- Outer sheath: LSZH
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania