CU/XLPE/AWA/LSZH BS 6724 1x185 mm²

Description

Description

Standards

  • Product
    BS 6724; IEC 60502

Applications:

Used in energy networks in hotels, schools, tunnels, high constructions,hospitals, power plants, data processing centers, business centers where there is a risk of fire

 

Construction:

  1. Conductor:Copper
  2. Insulation:XLPE
  3. Inner sheath:LSZH
  4. Armour:Single layer Aluminium wire
  5. Outer sheath:LSZH

 

Marking

ELECTRIC CABLE  600/1000 V  BS 6724  H  NEXANS i 

Nb. of cores  x cross section  "YEAR"  BASEC  

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor shape
Circular stranded (RM)
Conductor material
Copper
Insulation
XLPE (Cross-linked Polyethylene)
Core identification
Brown
Armour type
Aluminium Wire
Outer sheath
LSZH
Conductor flexibility
Stranded class 2
Halogen free
IEC 60754-1
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
185 mm²
Outer Diameter
27 mm
Approximate weight
2250 kg/km
Number of cores
1

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
0.0991 Ohm/km
Perm. current rating in air 30°C - flat formation
618 A
Permissible current rating clipped direct
496 A
Permissible short circuit current conductor 1s
26.5 kA
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Short-circuit max. conductor temperature
250 °C
Operating temperature, range
-20 ... 60 °C
Bending factor when laying
8 (xD)
Flame retardant
IEC 60332-3 Cat. C
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C
Smoke density
IEC 61034
U.V resistance
Yes

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000088-TRDE
  • Certification Date : 6/1/21
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1008
  • Declared performance : Dca-s1,d2,a1

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close