N2XH Multi Core Cables Cca Class 5

Products

N2XH 4G120 0,6/1 kV

Nexans ref. 10582805 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey, green / yellow
  • With Green/Yellow core: Yes
  • Number of cores: 4
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 46.2 mm
  • Approximate weight: 5350 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
  • Permissible current rating in open air: 346 A
  • Permissible current rating when buried: 257 A

 

N2XH 4x150 0,6/1 kV

Nexans ref. 10582849 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • With Green/Yellow core: No
  • Number of cores: 4
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 51.6 mm
  • Approximate weight: 6640 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A

 

N2XH 5G240 0,6/1 kV

Nexans ref. 10582806 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey, green / yellow
  • With Green/Yellow core: Yes
  • Number of cores: 5
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 71.0 mm
  • Approximate weight: 13250 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0801 Ohm/km
  • Permissible current rating in open air: 538 A
  • Permissible current rating when buried: 375 A

 

Description

Description

Standards

  • Product
    IEC 60502-1

Application

N2XH cable is an installation/power cable widely used in applications requiring high levels of fire safety due to the significant number of human lives at stake, such as: 

  • Industrial and Commercial Electrical Installations
  • Electrical Panels and Control Panels
  • Domestic Applications
  • Installations in Public Places
  • Tunnels and Underground Infrastructures
  • Wiring for interior power and lighting circuits in dry environments

Installation

N2XH cable is fit for indoor application.
It can be installed in ducts, trunking, and conduits.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
-
With smaller neutral conductor
No
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
LSZH
Halogen free
IEC 60754-1
Conductor flexibility
Class 5
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
5 (xD)
Flame retardant
IEC 60332-3 Cat. C
Fire retardant
-
Smoke density
IEC 61034-2
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close