N2XH Control Cables B2ca Class

Products

N2XH 7G1.5 mm2

Nexans ref. 10541185 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 7
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 14.0 mm
  • Approximate weight: 280 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 15 A
  • Permissible current rating when buried: 14 A

 

N2XH 7G2.5 mm2

Nexans ref. 10541186 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 7
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 15.0 mm
  • Approximate weight: 360 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 21 A
  • Permissible current rating when buried: 18 A

 

N2XH 10G1.5 mm2

Nexans ref. 10541187 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 10
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 380 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 13 A
  • Permissible current rating when buried: 12 A

 

N2XH 10G2.5 mm2

Nexans ref. 10541188 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 10
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 19.0 mm
  • Approximate weight: 500 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 15 A

 

N2XH 12G1.5 mm2

Nexans ref. 10541189 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 12
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 400 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 12 A
  • Permissible current rating when buried: 10 A

 

N2XH 12G2.5 mm2

Nexans ref. 10541190 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 12
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 19.0 mm
  • Approximate weight: 550 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 16 A
  • Permissible current rating when buried: 14 A

 

N2XH 14G1.5 mm2

Nexans ref. 10541191 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 14
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 460 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 12 A
  • Permissible current rating when buried: 10 A

 

N2XH 14G2.5 mm2

Nexans ref. 10541192 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 14
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 600 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 16 A
  • Permissible current rating when buried: 14 A

 

N2XH 16G1.5 mm2

Nexans ref. 10541193 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 16
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 19.0 mm
  • Approximate weight: 500 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 10 A
  • Permissible current rating when buried: 9 A

 

N2XH 16G2.5 mm2

Nexans ref. 10541194 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 16
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 21.0 mm
  • Approximate weight: 700 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 14 A
  • Permissible current rating when buried: 12 A

 

N2XH 19G1.5 mm2

Nexans ref. 10541195 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 19
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 550 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 10 A
  • Permissible current rating when buried: 9 A

 

N2XH 19G2.5 mm2

Nexans ref. 10541196 - Country ref. TR

  • Packaging: Drum (1000m)
  • Number of cores: 19
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 22.0 mm
  • Approximate weight: 750 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 14 A
  • Permissible current rating when buried: 12 A

 

Description

Description

Standards

  • Product
    IEC 60502-1

Application

Control cables used in energy networks in hotels, schools, tunnels, high constructions, hospitals, power plants, data processing centers, business centers where there is a risk of fire.

Construction

  1. Conductor:Copper
  2. Insulation:XLPE
  3. Filler:LSZH
  4. Outer sheath:LSZH

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular stranded (RM)
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
LSZH
Halogen free
IEC 60754-1
Conductor flexibility
Stranded class 2
Core identification
Black cores with white numbers + green/ yellow
Sheath colour
Black
With Green/Yellow core
Yes

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
8 (xD)
Flame retardant
IEC 60332-3 Cat. C
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Fire retardant
-
Max. conductor temperature in service
90 °C
Packaging
-

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close