N2XRH (IEC)
N2XRH (IEC)
0.6/1 kV XLPE insulated steel wire armoured multi-core cables with copper conductor
Read moreN2XRH 2x1.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 1.5 mm²
- Approximate weight: 260 kg/km
- Nominal outer diameter: 12.0 mm
- Number of cores: 2
- Conductor electrical resistance: 12.1 Ohm/km
- Permissible current rating in open air: 26 A
- Permissible current rating when buried: 27 A
N2XRH 2x10 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 10 mm²
- Approximate weight: 650 kg/km
- Nominal outer diameter: 18.0 mm
- Number of cores: 2
- Conductor electrical resistance: 1.83 Ohm/km
- Permissible current rating in open air: 86 A
- Permissible current rating when buried: 77 A
N2XRH 2x16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 16 mm²
- Approximate weight: 850 kg/km
- Nominal outer diameter: 20.0 mm
- Number of cores: 2
- Conductor electrical resistance: 1.15 Ohm/km
- Permissible current rating in open air: 115 A
- Permissible current rating when buried: 100 A
N2XRH 2x2.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 2.5 mm²
- Approximate weight: 300 kg/km
- Nominal outer diameter: 13.0 mm
- Number of cores: 2
- Conductor electrical resistance: 7.41 Ohm/km
- Permissible current rating in open air: 36 A
- Permissible current rating when buried: 35 A
N2XRH 2x25 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 25 mm²
- Approximate weight: 1300 kg/km
- Nominal outer diameter: 23.0 mm
- Number of cores: 2
- Conductor electrical resistance: 0.727 Ohm/km
- Permissible current rating in open air: 149 A
- Permissible current rating when buried: 129 A
N2XRH 2x35 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 35 mm²
- Approximate weight: 1600 kg/km
- Nominal outer diameter: 25.0 mm
- Number of cores: 2
- Conductor electrical resistance: 0.524 Ohm/km
- Permissible current rating in open air: 185 A
- Permissible current rating when buried: 155 A
N2XRH 2x4 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 4 mm²
- Approximate weight: 360 kg/km
- Nominal outer diameter: 14.0 mm
- Number of cores: 2
- Conductor electrical resistance: 4.61 Ohm/km
- Permissible current rating in open air: 49 A
- Permissible current rating when buried: 46 A
N2XRH 2x50 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 50 mm²
- Approximate weight: 2000 kg/km
- Nominal outer diameter: 28.0 mm
- Number of cores: 2
- Conductor electrical resistance: 0.387 Ohm/km
- Permissible current rating in open air: 225 A
- Permissible current rating when buried: 183 A
N2XRH 2x6 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 6 mm²
- Approximate weight: 440 kg/km
- Nominal outer diameter: 15.0 mm
- Number of cores: 2
- Conductor electrical resistance: 3.08 Ohm/km
- Permissible current rating in open air: 63 A
- Permissible current rating when buried: 58 A
N2XRH 2x70 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 70 mm²
- Approximate weight: 2750 kg/km
- Nominal outer diameter: 32.0 mm
- Number of cores: 2
- Conductor electrical resistance: 0.268 Ohm/km
- Permissible current rating in open air: 289 A
- Permissible current rating when buried: 225 A
N2XRH 2x95 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown
- Conductor cross-section: 95 mm²
- Approximate weight: 3500 kg/km
- Nominal outer diameter: 37.0 mm
- Number of cores: 2
- Conductor electrical resistance: 0.193 Ohm/km
- Permissible current rating in open air: 352 A
- Permissible current rating when buried: 270 A
N2XRH 3x1.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 1.5 mm²
- Approximate weight: 280 kg/km
- Nominal outer diameter: 13.0 mm
- Number of cores: 3
- Conductor electrical resistance: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
N2XRH 3x10 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 10 mm²
- Approximate weight: 800 kg/km
- Nominal outer diameter: 19.0 mm
- Number of cores: 3
- Conductor electrical resistance: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
N2XRH 3x120 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 120 mm²
- Approximate weight: 5500 kg/km
- Nominal outer diameter: 43.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.153 Ohm/km
- Permissible current rating in open air: 346 A
- Permissible current rating when buried: 257 A
N2XRH 3x150 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 150 mm²
- Approximate weight: 6750 kg/km
- Nominal outer diameter: 48.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.124 Ohm/km
- Permissible current rating in open air: 399 A
- Permissible current rating when buried: 287 A
N2XRH 3x16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 16 mm²
- Approximate weight: 1000 kg/km
- Nominal outer diameter: 21.0 mm
- Number of cores: 3
- Conductor electrical resistance: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
N2XRH 3x185 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 185 mm²
- Approximate weight: 8250 kg/km
- Nominal outer diameter: 53.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.099 Ohm/km
- Permissible current rating in open air: 456 A
- Permissible current rating when buried: 324 A
N2XRH 3x2.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 2.5 mm²
- Approximate weight: 340 kg/km
- Nominal outer diameter: 14.0 mm
- Number of cores: 3
- Conductor electrical resistance: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
N2XRH 3x240 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 240 mm²
- Approximate weight: 10500 kg/km
- Nominal outer diameter: 59.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.075 Ohm/km
- Permissible current rating in open air: 538 A
- Permissible current rating when buried: 375 A
N2XRH 3x25 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 25 mm²
- Approximate weight: 1600 kg/km
- Nominal outer diameter: 25.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
N2XRH 3x300 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 300 mm²
- Approximate weight: 12500 kg/km
- Nominal outer diameter: 65.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.06 Ohm/km
- Permissible current rating in open air: 621 A
- Permissible current rating when buried: 419 A
N2XRH 3x35 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 35 mm²
- Approximate weight: 1900 kg/km
- Nominal outer diameter: 27.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
N2XRH 3x4 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 4 mm²
- Approximate weight: 420 kg/km
- Nominal outer diameter: 15.0 mm
- Number of cores: 3
- Conductor electrical resistance: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
N2XRH 3x400 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 400 mm²
- Approximate weight: 15500 kg/km
- Nominal outer diameter: 72.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.047 Ohm/km
- Permissible current rating in open air: 721 A
- Permissible current rating when buried: 464 A
N2XRH 3x50 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 50 mm²
- Approximate weight: 2500 kg/km
- Nominal outer diameter: 30.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
N2XRH 3x6 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 6 mm²
- Approximate weight: 500 kg/km
- Nominal outer diameter: 16.0 mm
- Number of cores: 3
- Conductor electrical resistance: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
N2XRH 3x70 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 70 mm²
- Approximate weight: 3500 kg/km
- Nominal outer diameter: 35.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
N2XRH 3x95 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Brown, black, grey
- Conductor cross-section: 95 mm²
- Approximate weight: 4500 kg/km
- Nominal outer diameter: 39.0 mm
- Number of cores: 3
- Conductor electrical resistance: 0.193 Ohm/km
- Permissible current rating in open air: 298 A
- Permissible current rating when buried: 226 A
N2XRH 4x1.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 1.5 mm²
- Approximate weight: 320 kg/km
- Nominal outer diameter: 13.0 mm
- Number of cores: 4
- Conductor electrical resistance: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
N2XRH 4x10 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 10 mm²
- Approximate weight: 900 kg/km
- Nominal outer diameter: 20.0 mm
- Number of cores: 4
- Conductor electrical resistance: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
N2XRH 4x120 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 120 mm²
- Approximate weight: 7000 kg/km
- Nominal outer diameter: 49.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.153 Ohm/km
- Permissible current rating in open air: 346 A
- Permissible current rating when buried: 257 A
N2XRH 4x150 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 150 mm²
- Approximate weight: 8500 kg/km
- Nominal outer diameter: 53.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.124 Ohm/km
- Permissible current rating in open air: 399 A
- Permissible current rating when buried: 287 A
N2XRH 4x16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 16 mm²
- Approximate weight: 1300 kg/km
- Nominal outer diameter: 23.0 mm
- Number of cores: 4
- Conductor electrical resistance: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
N2XRH 4x185 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 185 mm²
- Approximate weight: 10500 kg/km
- Nominal outer diameter: 58.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.099 Ohm/km
- Permissible current rating in open air: 456 A
- Permissible current rating when buried: 324 A
N2XRH 4x2.5 mm2
Nexans ref. 10530923 - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 2.5 mm²
- Approximate weight: 380 kg/km
- Nominal outer diameter: 14.0 mm
- Number of cores: 4
- Conductor electrical resistance: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
N2XRH 4x240 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 240 mm²
- Approximate weight: 13000 kg/km
- Nominal outer diameter: 65.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.075 Ohm/km
- Permissible current rating in open air: 538 A
- Permissible current rating when buried: 375 A
N2XRH 4x25 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 25 mm²
- Approximate weight: 1900 kg/km
- Nominal outer diameter: 27.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
N2XRH 4x300 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 300 mm²
- Approximate weight: 16000 kg/km
- Nominal outer diameter: 71.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.06 Ohm/km
- Permissible current rating in open air: 621 A
- Permissible current rating when buried: 419 A
N2XRH 4x35 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 35 mm²
- Approximate weight: 2500 kg/km
- Nominal outer diameter: 29.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
N2XRH 4x4 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 4 mm²
- Approximate weight: 480 kg/km
- Nominal outer diameter: 16.0 mm
- Number of cores: 4
- Conductor electrical resistance: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
N2XRH 4x50 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 50 mm²
- Approximate weight: 3000 kg/km
- Nominal outer diameter: 33.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
N2XRH 4x6 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 6 mm²
- Approximate weight: 700 kg/km
- Nominal outer diameter: 18.0 mm
- Number of cores: 4
- Conductor electrical resistance: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
N2XRH 4x70 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 70 mm²
- Approximate weight: 4250 kg/km
- Nominal outer diameter: 39.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
N2XRH 4x95 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey
- Conductor cross-section: 95 mm²
- Approximate weight: 5500 kg/km
- Nominal outer diameter: 43.0 mm
- Number of cores: 4
- Conductor electrical resistance: 0.193 Ohm/km
- Permissible current rating in open air: 298 A
- Permissible current rating when buried: 226 A
N2XRH 5x1.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 1.5 mm²
- Approximate weight: 360 kg/km
- Nominal outer diameter: 14.0 mm
- Number of cores: 5
- Conductor electrical resistance: 12.1 Ohm/km
- Permissible current rating in open air: 23 A
- Permissible current rating when buried: 23 A
N2XRH 5x10 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 10 mm²
- Approximate weight: 1100 kg/km
- Nominal outer diameter: 21.0 mm
- Number of cores: 5
- Conductor electrical resistance: 1.83 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 65 A
N2XRH 5x120 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 120 mm²
- Approximate weight: 8500 kg/km
- Nominal outer diameter: 53.0 mm
- Number of cores: 5
- Conductor electrical resistance: 0.153 Ohm/km
- Permissible current rating in open air: 346 A
- Permissible current rating when buried: 257 A
N2XRH 5x16 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 16 mm²
- Approximate weight: 1600 kg/km
- Nominal outer diameter: 25.0 mm
- Number of cores: 5
- Conductor electrical resistance: 1.15 Ohm/km
- Permissible current rating in open air: 100 A
- Permissible current rating when buried: 84 A
N2XRH 5x2.5 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 2.5 mm²
- Approximate weight: 440 kg/km
- Nominal outer diameter: 15.0 mm
- Number of cores: 5
- Conductor electrical resistance: 7.41 Ohm/km
- Permissible current rating in open air: 32 A
- Permissible current rating when buried: 30 A
N2XRH 5x25 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 25 mm²
- Approximate weight: 2250 kg/km
- Nominal outer diameter: 29.0 mm
- Number of cores: 5
- Conductor electrical resistance: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 107 A
N2XRH 5x35 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 35 mm²
- Approximate weight: 2750 kg/km
- Nominal outer diameter: 32.0 mm
- Number of cores: 5
- Conductor electrical resistance: 0.524 Ohm/km
- Permissible current rating in open air: 158 A
- Permissible current rating when buried: 129 A
N2XRH 5x4 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 4 mm²
- Approximate weight: 650 kg/km
- Nominal outer diameter: 18.0 mm
- Number of cores: 5
- Conductor electrical resistance: 4.61 Ohm/km
- Permissible current rating in open air: 42 A
- Permissible current rating when buried: 39 A
N2XRH 5x50 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 50 mm²
- Approximate weight: 3750 kg/km
- Nominal outer diameter: 37.0 mm
- Number of cores: 5
- Conductor electrical resistance: 0.387 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 153 A
N2XRH 5x6 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 6 mm²
- Approximate weight: 800 kg/km
- Nominal outer diameter: 20.0 mm
- Number of cores: 5
- Conductor electrical resistance: 3.08 Ohm/km
- Permissible current rating in open air: 54 A
- Permissible current rating when buried: 49 A
N2XRH 5x70 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 70 mm²
- Approximate weight: 5000 kg/km
- Nominal outer diameter: 42.0 mm
- Number of cores: 5
- Conductor electrical resistance: 0.268 Ohm/km
- Permissible current rating in open air: 246 A
- Permissible current rating when buried: 188 A
N2XRH 5x95 mm2
Nexans ref. - Country ref. TR
- Packaging: Drum (500m)
- Core identification: Blue, brown, black, grey, green / yellow
- Conductor cross-section: 95 mm²
- Approximate weight: 7000 kg/km
- Nominal outer diameter: 48.0 mm
- Number of cores: 5
- Conductor electrical resistance: 0.193 Ohm/km
- Permissible current rating in open air: 298 A
- Permissible current rating when buried: 226 A
Description
Description
Standards
-
ProductIEC 60502-1
-
NationalTS IEC 60502
Application
Used in energy networks in hotels, schools, tunnels, high constructions,hospitals, power plants, data processing centers, business centers where there is a risk of fire
Construction
- Conductor:Copper
- Insulatıon:XLPE
- Filler:LSZH
- Armour:Single layer galvanized round steel wires
- Outer Sheath:LSZH
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania