N2XCH Screened Cables B2ca Class

Products

N2XCH 1x150/70 mm2

Nexans ref. 10576401 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Black
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Screen section: 70 mm²
  • Outer Diameter: 27.5 mm
  • Approximate weight: 2240 kg/km
  • Permissible current rating in open air: 577 A
  • Permissible current rating when buried: 287 A
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible short circuit current screen 1s: 21.4 kA

 

N2XCH 3G2.5/2.5 mm2

Nexans ref. 10576404 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Screen section: 2.5 mm²
  • Outer Diameter: 12.9 mm
  • Approximate weight: 240 kg/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 28 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible short circuit current screen 1s: .36 kA

 

N2XCH 3x2.5/2.5 mm2

Nexans ref. 10577335 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Brown, black, grey
  • Number of cores: 3
  • Conductor cross-section: 2.5 mm²
  • Screen section: 2.5 mm²
  • Outer Diameter: 11.1 mm
  • Approximate weight: 240 kg/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 28 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible short circuit current screen 1s: .36 kA

 

N2XCH 4x2.5/2.5 mm2

Nexans ref. 10556524 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 2.5 mm²
  • Screen section: 2.5 mm²
  • Outer Diameter: 13 mm
  • Approximate weight: 300 kg/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 30 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible short circuit current screen 1s: .37 kA

 

N2XCH 4x4/4 mm2

Nexans ref. 10556674 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Screen section: 4 mm²
  • Outer Diameter: 15 mm
  • Approximate weight: 400 kg/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 39 A
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible short circuit current screen 1s: .58 kA

 

N2XCH 4x4/4 mm2

Nexans ref. 10576402 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 4 mm²
  • Screen section: 4 mm²
  • Outer Diameter: 15.1 mm
  • Approximate weight: 370 kg/km
  • Permissible current rating in open air: 42 A
  • Permissible current rating when buried: 36 A
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible short circuit current screen 1s: .57 kA

 

N2XCH 4x6/6 mm2

Nexans ref. 10556675 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 6 mm²
  • Screen section: 6 mm²
  • Outer Diameter: 17 mm
  • Approximate weight: 550 kg/km
  • Permissible current rating in open air: 54 A
  • Permissible current rating when buried: 49 A
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible short circuit current screen 1s: .81 kA

 

N2XCH 4x10/10 mm2

Nexans ref. 10556676 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 10 mm²
  • Screen section: 10 mm²
  • Outer Diameter: 19 mm
  • Approximate weight: 800 kg/km
  • Permissible current rating in open air: 75 A
  • Permissible current rating when buried: 65 A
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible short circuit current screen 1s: 1.4 kA

 

N2XCH 4x16/16 mm2

Nexans ref. 10556681 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 16 mm²
  • Screen section: 16 mm²
  • Outer Diameter: 22 mm
  • Approximate weight: 1100 kg/km
  • Permissible current rating in open air: 100 A
  • Permissible current rating when buried: 84 A
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH 4x25/16 mm2

Nexans ref. 10556680 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 25 mm²
  • Screen section: 16 mm²
  • Outer Diameter: 26 mm
  • Approximate weight: 1600 kg/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 107 A
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH 4x35/16 mm2

Nexans ref. 10556677 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 35 mm²
  • Screen section: 16 mm²
  • Outer Diameter: 28 mm
  • Approximate weight: 2000 kg/km
  • Permissible current rating in open air: 158 A
  • Permissible current rating when buried: 129 A
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible short circuit current screen 1s: 2.17 kA

 

N2XCH 4x50/25 mm2

Nexans ref. 10556678 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 50 mm²
  • Screen section: 25 mm²
  • Outer Diameter: 32 mm
  • Approximate weight: 2750 kg/km
  • Permissible current rating in open air: 192 A
  • Permissible current rating when buried: 153 A
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible short circuit current screen 1s: 3.3 kA

 

N2XCH 4x150/70 mm2

Nexans ref. 10556682 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 150 mm²
  • Screen section: 70 mm²
  • Outer Diameter: 51 mm
  • Approximate weight: 7750 kg/km
  • Permissible current rating in open air: 399 A
  • Permissible current rating when buried: 287 A
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible short circuit current screen 1s: 8.96 kA

 

N2XCH 4x240/120 mm2

Nexans ref. 10556679 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown, black, grey
  • Number of cores: 4
  • Conductor cross-section: 240 mm²
  • Screen section: 120 mm²
  • Outer Diameter: 64 mm
  • Approximate weight: 12500 kg/km
  • Permissible current rating in open air: 538 A
  • Permissible current rating when buried: 375 A
  • Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
  • Permissible short circuit current screen 1s: 15.04 kA

 

N2XCH 5G2.5/2.5 mm2

Nexans ref. 10576403 - Country ref. TR

  • Packaging: Drum (1000m)
  • Core identification: Blue, brown
  • Number of cores: 5
  • Conductor cross-section: 2.5 mm²
  • Screen section: 2.5 mm²
  • Outer Diameter: 14.7 mm
  • Approximate weight: 320 kg/km
  • Permissible current rating in open air: 32 A
  • Permissible current rating when buried: 28 A
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible short circuit current screen 1s: .36 kA

 

Description

Description

Standards

  • Product
    IEC 60502-1

Application

Used in energy networks in hotels, schools, tunnels, high constructions, hospitals, power plants, data processing centers, business centers where there is a risk of fire.Incase of mechanical damage the screen prevents any damage due to power leak to the surrounding.

Construction

  1. Conductor:copper
  2. Insulation:XLPE
  3. Filler:LSZH
  4. Concentric screen:Copper wire + copper tape
  5. Outher sheath:LSZH

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor shape
-
Conductor flexibility
-
Conductor material
Copper
Halogen free
-
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
LSZH
Screen
Copper wires + copper tape
Sheath colour
Black

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Smoke density
IEC 61034
Bending factor when laying
8 (xD)
Flame retardant
IEC 60332-3 Cat. C
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close