YVCV 3x150/70 mm2

Description

Description

Standards

  • National
    TS IEC 60502

Application:

Mainly laid underground in populated areas. In case of mechanical damage the screen prevents any damage due to power leak to the surrounding area.

 

Construction:

  1. Conductor:Copper
  2. Insulatıon:PVC
  3. Filler
  4. Concentric screen:Copper wires + copper tape
  5. Outer Sheath:PVC

 

Marking:

<>TSE<> NEXANS TS IEC 60502 YVCV  Number of cores x cross section 0.6/1 kV ''YEAR''

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
PVC
Material of filler / inner sheath
Butyl + PVC
Outer sheath
PVC
Conductor flexibility
Stranded class 2
Conductor shape
Circular stranded (RM)
Core identification
Brown, black, grey
Screen
Concentric copper
Sheath colour
Black
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Approximate weight
6500 kg/km
Conductor cross-section
150 mm²
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
48.0 mm
Number of cores
3
Screen section
70 mm²

Electrical characteristics

Electrical characteristics

Conductor electrical resistance
0.124 Ohm/km
Permissible current rating in open air
319 A
Permissible current rating when buried
246 A
Permissible short circuit current screen 1s
- kA
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Bending factor when installed
8 (xD)
Flame retardant
IEC 60332-1-2
Maximum operating temperature
70 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000668-TRDE
  • Certification Date : 3/8/18
  • AVCP (Assessment and Verification of Constancy of Performance) : System 4
  • Declared performance : Fca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close