YVZ2V 3x1.5 mm2

Nexans ref. 10530115 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 320 kg/km
  • Nominal outer diameter: 13.0 mm
  • Number of cores: 3
  • Conductor electrical resistance: 12.1 Ohm/km
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 19 A

 

YVZ2V 3x10 mm2

Nexans ref. 10531020 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 10 mm²
  • Approximate weight: 950 kg/km
  • Nominal outer diameter: 20.0 mm
  • Number of cores: 3
  • Conductor electrical resistance: 1.83 Ohm/km
  • Permissible current rating in open air: 60 A
  • Permissible current rating when buried: 54 A

 

YVZ2V 3x2.5 mm2

Nexans ref. 10519144 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 380 kg/km
  • Nominal outer diameter: 13.0 mm
  • Number of cores: 3
  • Conductor electrical resistance: 7.41 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 24 A

 

YVZ2V 3x4 mm2

Nexans ref. 10531018 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 4 mm²
  • Approximate weight: 550 kg/km
  • Nominal outer diameter: 16.0 mm
  • Number of cores: 3
  • Conductor electrical resistance: 4.61 Ohm/km
  • Permissible current rating in open air: 34 A
  • Permissible current rating when buried: 33 A

 

YVZ2V 3x6 mm2

Nexans ref. 10531019 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 6 mm²
  • Approximate weight: 700 kg/km
  • Nominal outer diameter: 18.0 mm
  • Number of cores: 3
  • Conductor electrical resistance: 3.08 Ohm/km
  • Permissible current rating in open air: 43 A
  • Permissible current rating when buried: 41 A

 

YVZ2V 4x1.5 mm2

Nexans ref. 10519143 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 1.5 mm²
  • Approximate weight: 360 kg/km
  • Nominal outer diameter: 13.0 mm
  • Number of cores: 4
  • Conductor electrical resistance: 12.1 Ohm/km
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 19 A

 

YVZ2V 4x10 mm2

Nexans ref. 10531021 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 10 mm²
  • Approximate weight: 1100 kg/km
  • Nominal outer diameter: 21.0 mm
  • Number of cores: 4
  • Conductor electrical resistance: 1.83 Ohm/km
  • Permissible current rating in open air: 60 A
  • Permissible current rating when buried: 54 A

 

YVZ2V 4x2.5 mm2

Nexans ref. 10519142 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 2.5 mm²
  • Approximate weight: 420 kg/km
  • Nominal outer diameter: 14.0 mm
  • Number of cores: 4
  • Conductor electrical resistance: 7.41 Ohm/km
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 24 A

 

YVZ2V 4x4 mm2

Nexans ref. 10530116 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 4 mm²
  • Approximate weight: 700 kg/km
  • Nominal outer diameter: 18.0 mm
  • Number of cores: 4
  • Conductor electrical resistance: 4.61 Ohm/km
  • Permissible current rating in open air: 34 A
  • Permissible current rating when buried: 33 A

 

YVZ2V 4x6 mm2

Nexans ref. 10519141 - Country ref. TR

  • Packaging: Drum (500m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 6 mm²
  • Approximate weight: 800 kg/km
  • Nominal outer diameter: 19.0 mm
  • Number of cores: 4
  • Conductor electrical resistance: 3.08 Ohm/km
  • Permissible current rating in open air: 43 A
  • Permissible current rating when buried: 41 A

 

Description

Description

Standards

  • International
    IEC 60502-1
  • National
    TS IEC 60502

Application

Is most suitable in areas where mechanical damage is a possibility. Can be laid outdoors, indoors, underground and in ducts.

 

Construction

  1. Conductor:Copper
  2. Insulatıon:PVC
  3. Filler:PVC
  4. Armour:Single layer galvanized round steel wires
  5. Outer Sheath:PVC

 

Marking

<>TSE<> NEXANS TS IEC 60502 YVZ2V Number of cores x cross section 0,6/1 kV YEAR

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanised round steel wires
Conductor material
Copper
Insulation
PVC
Material of filler / inner sheath
PVC
Outer sheath
PVC
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Delivery reel size for 1000m
500 cm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Bending factor when laying
12 (xD)
Flame retardant
IEC 60332-1-2
Laying operation bending radius
- mm
Maximum operating temperature
70 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close