YVV (NYY) 1x50 mm2

Description

Description

Standards

  • Product
    IEC 60502-1
  • National
    TS IEC 60502

Application:

Used as lighting and power distrubution cable. Installed in areas where severe mechanical stress is avoided. Can be laid in doors, outdoors, buried or in tranches

 

Construction:

  1. Conductor:Copper
  2. Insulation:PVC
  3. Outer sheath:PVC

 

Marking:

<>TSE<> NEXANS TS IEC 60502 YVV Number of cores x cross section  0,6/1 kV  "YEAR"

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular stranded (RM)
Insulation
PVC
Outer sheath
PVC
Conductor flexibility
Stranded class 2
Core identification
Black
Sheath colour
Black
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
50 mm²
Approximate weight
550 kg/km
Nominal outer diameter
13.0 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Conductor electrical resistance
0.387 Ohm/km
Perm. current rating buried 20°C - flat formation
- A
Perm. current rating buried 20°C - trefoil formation
130 A
Perm. current rating in air 30°C - flat formation
- A
Perm. current rating in air 30°C - trefoil formation
167 A
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Bending factor when laying
12 (xD)
Flame retardant
IEC 60332-1-2
Maximum operating temperature
70 °C
Operating temperature, range
-20 ... 60 °C
Packaging
Drum
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000413-TRDE
  • Certification Date : 6/24/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1783
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close