NYY 5G95 mm2

Description

Description

Standards

  • Product
    IEC 60502-1
  • National
    TS IEC 60502

Application

Used as lighting and power distrubution cable. Installed in areas where severe mechanical stress is avoided. Can be laid in doors, outdoors buried or in cable tranches.

Construction

  1. Conductor:Copper
  2. Insulation:PVC
  3. Filler:PVC
  4. Outer Sheath:PVC

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular stranded (RM)
Insulation
PVC
Outer sheath
PVC
Conductor flexibility
Stranded class 2
Core identification
Blue, brown, black, grey, green / yellow
Sheath colour
Black
With Green/Yellow core
Yes
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
95 mm²
Approximate weight
5840 kg/km
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
46.0 mm
Number of cores
5

Electrical characteristics

Electrical characteristics

Conductor electrical resistance
0.193 Ohm/km
Max. DC resistance of the conductor at 20°C
0.193 Ohm/km
Permissible current rating in open air
238 A
Permissible current rating when buried
169 A
Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Bending factor when laying
8 (xD)
Flame retardant
IEC 60332-1-2
Maximum operating temperature
70 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000415-TRDE
  • Certification Date : 4/16/21
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1783
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close