NA2XS(FL)2Y - XRUHAKXS 1x400/35 mm2

Description

Description

Standards

  • Product
    IEC 60502-2

Application:

These are cables with low dielectric losses used in energy network with sudden load changes. Laid in residental or industrial areas, underground or in ducts.

 

Construction:

  1. Conductor:Aluminium
  2. Conductor screen:Semi-conducting compound (XLPE)
  3. Insulation:XLPE
  4. Insulation screen:Semi-conducting compound (XLPE) + water swelling tape + copper wires with counter helix of copper tape
  5. Outer sheath: Longitudinal Aluminium foil sticking to protective sheath PE

 

Marking:

NEXANS  IEC 60502 NA2XS(FL)2Y - XRUHAKXS Number of cores x cross section 18/30 kV  "YEAR"

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Circular compacted
Material of the inner semi-conductor
XLPE
Insulation
XLPE (Cross-linked Polyethylene)
Material of the external semi-conductor
XLPE
Screen
Copper wire + copper tape
Outer sheath
PE
Conductor flexibility
Stranded class 2
Halogen free
IEC 60754-1; IEC 60754-2
Longitudinally watertight
Yes
Radial waterproof
Yes
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Conductor cross-section
- mm²
Nominal outer diameter
45.5 mm
Approximate weight
2660 kg/km
Delivery reel size for 1000m
- cm
Screen section
- mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
18/30 kV
Max. DC resistance of the conductor at 20°C
0.078 Ohm/km
Characteristic impedance
- Ohm
Perm. current rating buried 20°C - flat formation
470 A
Perm. current rating in air 30°C - flat formation
769 A
Permissible short circuit current conductor 1s
37.6 kA
Permissible short circuit current screen 1s
- kA
Reactance at 50 Hz
- Ohm/km
Voltage Drop
0.25 V/A.km

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Bending factor when laying
12 (xD)
Longitudinal water tightness
Yes
Max. conductor temperature in service
90 °C
Radial water tightness
Yes
U.V resistance
Yes

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1001168-TRDE
  • Certification Date : 6/21/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 4
  • Declared performance : Fca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close