A-2YHBH H115/H145 (CU/PE/LSZH/STA/LSZH)

Products

A-2YHBH 10x1x0.9 mm

Nexans ref. 10557261 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 10x1x1.4 mm

Nexans ref. 10557268 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 1.4 mm
  • Nominal insulation thickness: 0.4 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 14x1x0.9 mm

Nexans ref. 10557262 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 20x1x0.9 mm

Nexans ref. 10557263 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 20x1x1.4 mm

Nexans ref. 10557269 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 1.4 mm
  • Nominal insulation thickness: 0.4 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 30x1x0.9 mm

Nexans ref. 10557264 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 4x1x0.9 mm

Nexans ref. 10557260 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 4x1x1.4 mm

Nexans ref. 10557267 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 1.4 mm
  • Nominal insulation thickness: 0.4 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 50x1x1.4 mm

Nexans ref. 10582747 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 1.4 mm
  • Nominal insulation thickness: 0.4 mm
  • Operating temperature, range: -30 ... 60 °C

 

A-2YHBH 60x1x0.9 mm

Nexans ref. 10557265 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 60x1x1.4 mm

Nexans ref. 10557270 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 1.4 mm
  • Nominal insulation thickness: 0.4 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 80x1x0.9 mm

Nexans ref. 10557266 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 0.9 mm
  • Nominal insulation thickness: 0.35 mm
  • Operating temperature, range: -30 ... 70 °C

 

A-2YHBH 80x1x1.4 mm

Nexans ref. 10557271 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor diameter: 1.4 mm
  • Nominal insulation thickness: 0.4 mm
  • Operating temperature, range: -30 ... 70 °C

 

Description

Description

Standards

  • Product
    DB LH 416.0113 version 2.1; DB LH 416.0114 version 2.1

Cable construction

1. Copper conductor wire: Solid 0.9mm / 1.4 mm

2. Insulation: Solid Polyethylene

Laying up: Twisted cores are helically stranded in layers*

3. Wrapping: One or more dielectric non hygroscopic tape

4. Inner sheath: Low smoke zero halogen compound - black

5. Bedding: Non-hygroscopic tape

6. Armour: Double layers of helically applied galvanized steel tapes.

7. Outer sheath : Black
Low smoke zero halogen compound

UV resistant

*Cables from 14 cores on, have two extra conductors of 0.5 mm with perforated insulation (surveillance conductors)

 

Core Identification:

First core is blue, others are natural in every layer.

Natural binder tape shall be applied between layers.

 

Marking:

00000 m SIGNAL A-2YHBH 7x1x1,4 S (H145) SIGNAL Year SIGNAL < NEXANS > SIGNAL 00001 m

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Insulation
Solid polyethylene
Outer sheath
LSZH compound
Sheath colour
Black
Halogen free
Yes
Armour type
Helically applied steel tapes

Dimensional characteristics

Dimensional characteristics

Armour thickness
0.25 mm

Usage characteristics

Usage characteristics

Length
1000 m
Packaging
Reel
Bending factor when installed
15 (xD)
Ambient installation temperature, range
-5 ... 50 °C
Fire retardant
IEC 60332-3-24 (cat C)
Smoke density
EN/IEC 61034-2
Dynamic bending factor
20 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close