YVCV (TSE) / NYCY (IEC) 0,6/1 kV

Products

YVCV 3x1.5/1.5 mm2

Nexans ref. 10530998 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 19 A

 

YVCV 4x1.5/1.5 mm2

Nexans ref. 10531012 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 19 A

 

NYCY 4x1.5/1.5 mm2

Nexans ref. 10545914 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 19 A

 

NYCY 3x1.5/1.5 mm2

Nexans ref. 10545915 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 18 A
  • Permissible current rating when buried: 19 A

 

NYCY 7x1.5/2.5 mm2

Nexans ref. 10545917 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Numbers
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 7
  • Permissible current rating in open air: 12 A
  • Permissible current rating when buried: 11 A

 

YVCV 3x2.5/2.5 mm2

Nexans ref. 10530999 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 24 A

 

YVCV 4x2.5/2.5 mm2

Nexans ref. 10530347 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 24 A

 

NYCY 4x2.5/2.5 mm2

Nexans ref. 10545912 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 24 A

 

NYCY 2x2.5/2.5 mm2

Nexans ref. 10545913 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 2
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 28 A

 

NYCY 4x2.5/2.5 mm2

Nexans ref. 10571411 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 25 A
  • Permissible current rating when buried: 24 A

 

NYCY 19x2.5/6 mm2

Nexans ref. 10571413 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Numbers
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 19
  • Permissible current rating in open air: 11 A
  • Permissible current rating when buried: 10 A

 

NYCY 7x2.5/2.5 mm2

Nexans ref. 10572377 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Numbers
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 7
  • Permissible current rating in open air: 16 A
  • Permissible current rating when buried: 14 A

 

YVCV 3x4/4 mm2

Nexans ref. 10531000 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 4 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 34 A
  • Permissible current rating when buried: 33 A

 

YVCV 4x4/4 mm2

Nexans ref. 10530348 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 4 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 34 A
  • Permissible current rating when buried: 33 A

 

NYCY 4x4/4 mm2

Nexans ref. 10545911 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 4 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 34 A
  • Permissible current rating when buried: 33 A

 

NYCY 2x4/4 mm2

Nexans ref. 10537175 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown
  • Conductor cross-section: 4 mm²
  • Number of cores: 2
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 38 A

 

NYCY 4x4/4 mm2

Nexans ref. 10571412 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 4 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 34 A
  • Permissible current rating when buried: 33 A

 

YVCV 3x6/6 mm2

Nexans ref. 10531001 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 6 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 43 A
  • Permissible current rating when buried: 41 A

 

YVCV 4x6/6 mm2

Nexans ref. 10521646 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 6 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 43 A
  • Permissible current rating when buried: 41 A

 

NYCY 4x6/6 mm2

Nexans ref. 10545839 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 6 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 43 A
  • Permissible current rating when buried: 41 A

 

NYCY 2x6/6 mm2

Nexans ref. 10545910 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown
  • Conductor cross-section: 6 mm²
  • Number of cores: 2
  • Permissible current rating in open air: 51 A
  • Permissible current rating when buried: 48 A

 

YVCV 3x10/10 mm2

Nexans ref. 10531002 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 10 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 60 A
  • Permissible current rating when buried: 54 A

 

YVCV 4x10/10 mm2

Nexans ref. 10531013 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 10 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 60 A
  • Permissible current rating when buried: 54 A

 

YVCV 3x16/16 mm2

Nexans ref. 10531003 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 16 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 80 A
  • Permissible current rating when buried: 70 A

 

YVCV 4x16/16 mm2

Nexans ref. 10531014 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 16 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 80 A
  • Permissible current rating when buried: 70 A

 

NYCY 3x16/16 mm2

Nexans ref. 10525856 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 16 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 80 A
  • Permissible current rating when buried: 64 A

 

YVCV 3x25/16 mm2

Nexans ref. 10531004 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 25 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 101 A
  • Permissible current rating when buried: 92 A

 

YVCV 4x25/16 mm2

Nexans ref. 10531015 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 25 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 101 A
  • Permissible current rating when buried: 92 A

 

YVCV 3x35/16 mm2

Nexans ref. 10531005 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 35 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 126 A
  • Permissible current rating when buried: 110 A

 

YVCV 4x35/16 mm2

Nexans ref. 10531016 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Blue, brown, black, grey
  • Conductor cross-section: 35 mm²
  • Number of cores: 4
  • Permissible current rating in open air: 126 A
  • Permissible current rating when buried: 110 A

 

YVCV 3x50/25 mm2

Nexans ref. 10531006 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 50 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 153 A
  • Permissible current rating when buried: 130 A

 

YVCV 3x70/35 mm2

Nexans ref. 10519009 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 70 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 196 A
  • Permissible current rating when buried: 162 A

 

YVCV 3x95/50 mm2

Nexans ref. 10531007 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 95 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 238 A
  • Permissible current rating when buried: 193 A

 

YVCV 3x120/70 mm2

Nexans ref. 10531008 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 120 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 276 A
  • Permissible current rating when buried: 220 A

 

YVCV 3x150/70 mm2

Nexans ref. 10531009 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 150 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 319 A
  • Permissible current rating when buried: 246 A

 

YVCV 3x185/95 mm2

Nexans ref. 10531010 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 185 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 364 A
  • Permissible current rating when buried: 278 A

 

YVCV 3x185/16 mm2

Nexans ref. 10564428 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 185 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 364 A
  • Permissible current rating when buried: 278 A

 

YVCV 3x240/120 mm2

Nexans ref. 10531011 - Country ref. TR

  • Packaging: Drum (1000m)
  • Conductor flexibility: Stranded class 2
  • Conductor shape: Circular stranded (RM)
  • Core identification: Brown, black, grey
  • Conductor cross-section: 240 mm²
  • Number of cores: 3
  • Permissible current rating in open air: 430 A
  • Permissible current rating when buried: 320 A

 

Description

Description

Standards

  • National
    TS IEC 60502

Application

Mainly laid underground in populated areas. In case of mechanical damage the screen prevents any damage due to power leak to the surrounding area.

Construction

  1. Conductor:Copper
  2. Insulatıon:PVC
  3. Filler
  4. Concentric screen:Copper wires + copper tape
  5. Outer Sheath:PVC

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
PVC
Outer sheath
PVC
Screen
Concentric copper
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Bending factor when installed
8 (xD)
Flame retardant
IEC 60332-1-2
Maximum operating temperature
70 °C
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close